Quantum Instruments DLT 7000 Cassette Player User Manual


 
General Description and Specifications
Quantum DLT 7000 Tape System 1-5
1.3.6 Environmental Specifications
The following tables provide the operating, non-operating, storage and shipping
environmental specifications for the DLT 7000 tape system.
Table 14 DLT 7000 Environmental Specifications
Specification Operating Limits Non-Operating Limits
(Power On; No Tape Loaded)
Wet Bulb Temperature 25°C (77°F) 25°C (77°F)
Dry Bulb Temperature
Range
10°C to 40°C (50°F to 104°F) 10°C to 40°C (50°F to 104°F)
Temperature Gradient 11°C (52°F) /hour (across range) 15°C (59°F) /hour (across range)
Temperature Shock 10°C (50°F) (over two minutes) 15°C (59°F) (over two minutes)
Relative Humidity 20% to 80% (non-condensing) 10% to 90% (non-condensing)
Humidity Gradient 10% / hour 10% / hour
Altitude Normal Pressure from -500 feet
to 30,000 feet
Airflow Velocity 125 Linear Feet per Minute
(LFM) measured directly in front
of the front bezel
Table 15 DLT 7000 Storage and Shipping Specifications
Description Storage (Unpacked or Packed) Shipping
Dry Bulb Temperature -40 to 66°C (-40 to 150°F) -40 to 150°F(-40 to 66°C)
Wet Bulb Temperature 46°C (114°F) 114°F (46°C)
Temperature Gradient 20°C (68°F) /hr with 5° margin
across the range
25°C (77°F) /hr with 5° margin
across the range
Temperature Shock 15°C (59°F) /hr with 5° margin
over 2 minutes
15°C (59°F) /hr with 5° margin
over 2 minutes
Relative Humidity 10 to 95%, non-condensing 10 to 95%, non-condensing
Humidity Gradient 10%/hr 10%/hr