Quantum Instruments DLT 7000 Cassette Player User Manual


 
SCSI Commands
Quantum DLT 7000 Tape System 5-151
REQUEST SENSE Command (03h) (continued)
Table 5–72 Supported ASC / ASCQ in Hex (continued)
Sense Key ASC ASCQ Description
MEDIUM ERROR
(cont.)
14 00 Recorded Entity Not Found (logical DLT block not
found)
15 02 Position Error Detected by Read of Medium
30 00 Cannot Read Medium
30 01 Unknown Format
3B 00 Sequential Positioning Error
3B 08 Repositioning Error
51 00 ERASE Failure
80 00 Calibration Error (use cleaning tape)
80 01 Cleaning Required (use cleaning tape)
81 00 Directory Read Error (use cleaning tape)
04h 08 00 LUN Communication Failure
HARDWARE ERROR 08 01 LUN Communication Timeout Failure
0C 80 Write SCSI FIFO CRC Error
11 80 Read SCSI FIFO CRC Error
11 81 Block Port Detected EDC Error
11 82 Block Port Detected Record CRC Error
15 01 Random Mechanical Positioning Error
21 01 Invalid Element Address
3B 08 Repositioning Error
3B 0D Media Destination Element Full
1
3B 0E Media Source Element Empty
1
40 80 Diagnostic/POST Failure, ROM EDC Error
2
40 81 Diagnostic/POST Failure, RAM Failure
2
40 82 Diagnostic/POST Failure, Bad Drive Status
2
40 83 Diagnostic/POST Failure, Loader Diagnostics
Failure
2
40 84 Diagnostic/POST Failure, POST Soft Failure
2
44 00 Internal Target Failure
44 83 SCSI Chip Gross Error/ Illegal – Command Status
44 84 Unexpected/Unexplained Residue Count in Transfer
Register
44 85 Immediate Data Transfer Timeout
44 86 Insufficient CDB Bytes
44 87 Disconnect/SDP Sequence Failed
44 88 Bus DMA Transfer Timeout
44 8A Over Temperature Condition
44 C1 EEPROM Copy 1 Area Bad
44 C2 EEPROM Copy 2 Area Bad
1
Medium changer specific command.
2
Contact a service representative.
3
Bad firmware image or code download possible.