Quantum Instruments DLT 7000 Cassette Player User Manual


 
SCSI Commands
5-162 Quantum DLT 7000 Tape System
SEND DIAGNOSTIC Command (1Dh) (continued)
NOTE
Because of data generation and verification, this test only streams
the tape for short periods of time. If Block Count is set very high,
the test can take many minutes or even many hours to complete.
If the specified diagnostic test passes, a GOOD status is returned. Otherwise, a
CHECK CONDITION is generated and the Sense Data contains information
about the failure.
Table 5–78 Sense Keys Used for SEND DIAGNOSTIC
Sense Key Description
3h Medium Error. A positioning error has occurred in which the returned position does
not match the expected position. Additional Sense Code for possible additional
information.
4h Hardware Error. The Additional Sense Code and any Additional Sense Code Qualifier
provide more specific information.
5h ILLEGAL REQUEST. Illegal bit settings in the SEND DIAGOSTIC command.
Eh Miscompare. A compare error occurred during a READ operation.
Additional Sense Codes and Additional Sense Code Qualifiers that apply to
SEND DIAGNOSTIC self-test results are described in the table below.
Table 5–79 ASC / ASCQ for SEND DIAGNOSTIC
ASC ASCQ Description
15h 2h A positioning error has occurred in which the returned position does
not match the expected position.
40h 80h Level 1 ROM Test Failed.
40h 81h Level 1 RAM Test Failed.
40h 82h Level 1 Test Failed. Bad Drive Status.
40h 83h Level 1 Test Failed. Loader Reset Failed.