Quantum Instruments DLT 7000 Cassette Player User Manual


 
SCSI Commands
Quantum DLT 7000 Tape System 5-153
REQUEST SENSE Command (03h) (continued)
Table 5–72 Supported ASC / ASCQ in Hex (continued)
Sense Key ASC ASCQ Description
06h 28 00 Not Ready To Ready Transition
UNIT ATTENTION 29 00 Reset Occurred
2A 01 Mode Parameters Changed
2A 02 Log Parameters Changed
3F 01 Microcode has been Changed
5B 01 Log Threshold Condition Met
07h 27 80 Hardware WRITE Protect
DATA PROTECTED 27 82 Data Safety WRITE Protect (if Use Cleaning Tape LED
is lit, use a cleaning tape)
08h 00 05 EOD Encountered
BLANK CHECK 08 00 LUN Communications Failure
01 LUN Communications Time-out
09h
VENDOR UNIQUE
XX YY Code Update Event (where XX = Drive revision
code; YY = Controller revision code)
0Ah 0A 00 Error Log Overflow
80 Error Log Generated
0Bh 2F 00 Commands Cleared by Another Initiator
COMMAND 43 00 Message Error
ABORTED 44 80 Unexpected Selection Interrupt
44 82 Command Complete Sequence Failure
44 83 SCSI Chip, Gross Error/ Illegal – Command Status
44 84 Unexpected/Unexplained Residue Count in Transfer
Register
44 87 Disconnect Sequence Failed
44 89 Command Cleared from Queue Without Other
45 00 Select/Reselect Failure
47 00 SCSI Parity Error (check SCSI bus configuration and
connections)
1
Medium changer specific command.
2
Contact a service representative.
3