Quantum Instruments DLT 7000 Cassette Player User Manual


 
SCSI Commands
Quantum DLT 7000 Tape System 5-99
MODE SELECT (6) / (10) Command (15h) / (55h) (continued)
An example follows that illustrates an EEPROM vendor unique page that
modifies the FORCEDENSITY parameter to 4.
0 0 0 Page Code (3Eh)
1 Page Length (0Fh)
2 “F” (46h)
3 “O” (4Fh)
4 “R” (52h)
5 “C” (43h)
6 “E” (45h)
7 “D” (44h)
8 “E” (45h)
9 “N” (4Eh)
10 “S” (53h)
11 “I” (49h)
12 “T” (54h)
13 “Y” (59h)
14 “ ” (20h)
15 “4” (ASCII) (34h)
16 <LF> (A0h) or (00h)
Figure 5–46 EEPROM Vendor Unique Page “Forced Density” Example - Data Format