Quantum Instruments DLT 7000 Cassette Player User Manual


 
SCSI Commands
5-120 Quantum DLT 7000 Tape System
MODE SENSE (6) / (10) Command (1Ah / 5Ah) (continued)
Table 5–57 Device Configuration Page - Field Descriptions (continued)
Field Name Description
SOCF Stop on Consecutive Filemarks. Set to 0.
RBO Recover Buffer Order. Set to 0.
REW Report Early Warning. Set to 0 (do not report early warning EOM on
reads).
Gap Size Not supported. Set to 0.
EOD Defined End of Data. Set to 00h.
EEG Enable EOD Generation Bit. Set to 1 to indicate that the drive
generates an EOD. The drive generates an EOD mark before any
change of direction following a WRITE-type operation.
SEW Synchronize at Early Warning. Set to 1.
Buffer Size at Early
Warning
Not supported; must be 0.
Select Data Compression
Algorithm
If set to 1, data compression is enabled. If 0, data compression is
disabled.