B.7 Power Supply – AC Mains Input
This equipment is fitted with a wide-ranging power supply. It is suitable for supply
voltages of 100-240 V AC -10% +6% at 50/60 Hz nominal.
Table B.25 AC Power Supply Specification
Item Specification
Power distribution system
Type TN ONLY (EN 60950-1 Annex V): Power distribution
system which is directly earthed, the parts of the equipment
required to be earthed being connected by protective
earthing conductors. This equipment must NOT be used
with single-phase three-wire and PE, TT or IT Type Power
distribution systems.
Connection to supply
Pluggable Equipment Type A (EN 60950-1 para 1.2.5):
Equipment which is intended for connection to the building
power supply wiring via a non-industrial plug and
socket-outlet or a non-industrial appliance Coupler or both.
Correct mains polarity must always be observed. Do not
use reversible plugs with this equipment.
Class of equipment
Class I Equipment (EN 60950-1 para 1.2.4): electric shock
protection by basic insulation and protective earth.
Rated voltage 100-240 V AC (single phase)
Rated frequency 50/60 Hz
Voltage selection Wide-ranging
Rated current
RX83xx: 1 A (100-240 V AC range)
RX82xx: 1.5 A (100-240 V AC range)
Input connector CEE 22/IEC 3-pin male receptacle
Fuse
Fuse in live conductor in power input filter at rear of unit. Do
not use reversible plugs with this equipment.
Fuse type Bussmann S505
Littelfuse 215
5x20 mm time delay (T) 1500 A breaking capacity (HBC)
IEC/EN 60127-2 Sheet 5
Fuse current rating All RX8000 models: 2 A 250 V T HBC
Power consumption
45 W typical (NO options fitted)
60 W maximum
B.8 Cable Types
The signal cable types (or similar) in Table B.26 are those recommended by
Ericsson in order to maintain product EMC compliance.
EN/LZT 790 0005 R1A
B-20