Klark Teknik DN9344E Stereo Equalizer User Manual


 
Operation: DN9344E
53
15.5. Digital Output Clock Select (Pages 5 and 6)
The next two pages select the clock reference for the digital AES/EBU outputs 1 and 2. Note that the
output clock reference settings are independent of sampling frequency. The available options are:
‘INT’ – the digital output is locked to the DN9344E’s internal system clock. Note that this is
the default setting.
‘WCK’ – the digital output is locked to the word clock reference input located on the rear
panel of the unit.
‘I1D’ or ‘I2D’ – the digital output is locked to the digital input channel’s incoming AES/EBU bit
stream from either input 1 or input 2.
Note The available options for may be affected by the set-up of the input
source and clock selects, see Appendix A for details.
To change the settings for Output 1
1 Step through the Set Up menus to the Output 1 page (“O1”) shown below:
2 Use the UP and DOWN buttons on the left-hand half of the unit (Section 1) to navigate between
each of the four display fields.
3 Now use the UP and DOWN buttons on the right-hand half of the unit (Section 2) to change to a
new option.
4 Press SETUP to confirm (unit will display password menu).
5 Press SETUP to exit.
Note The available options for each field may be affected by the set-up of
other fields.