Klark Teknik DN9344E Stereo Equalizer User Manual


 
Controls, Connectors, Indicators: DN9340E
11
1
4. REAR PANEL: DN9340E
1 Mains
inlet socket
Mains inlet unit is auto sensing over the range 100-240V AC.
2 Ethernet 2-port Ethernet switch for remote control using Cat-5
cabling.
3 RS-232 serial interface RS-232 serial interface for Solo Tracking System operation
in association with MIDAS consoles.
4 Inputs A and B
Analogue – electronically balanced XLR audio input sockets
Pinouts: Pin 1 Screen
Pin 2 Hot
Pin 3 Cold
Digital – input A supports incoming 96kHz AES/EBU signals.
Note that when digital input is selected, input B is inactive.
AES/EBU is 110 Ohms. Sample rate converters (SRCs)
support incoming signals at sampling frequencies from
32kHz to 96kHz ± 12.5%, while allowing the unit to operate
internally at 48kHz. An SRC bypass facility is available for
48kHz operation, to eliminate the propagation delay through
the SRC.
Pinouts: Pin 1 Screen
Pin 2 Data +
Pin 3 Data -
5 Analogue Outputs A
and B
Electronically balanced XLR audio output plugs
Pinouts: Pin 1 Screen
Pin 2 Hot
Pin 3 Cold
6 Digital Outputs A and B Digital AES/EBU output for channels A and B.
AES/EBU is 110 Ohms.
7 Word clock Input A word clock input is provided for synchronisation purposes.
2 3 4 4 5
5