Klark Teknik DN9344E Stereo Equalizer User Manual


 
Operation: DN9344E
50
To select a remote communications channel
1 Press and hold the SET UP button to open the Comms menu. Note that the red alphanumeric
displays are now showing Last Recalled Memory and Communication (COMMS) mode. The
blue display mode indicator illuminates to emphasise this fact. The UP and DOWN buttons
illuminate to show that they are now active.
2 Press UP and DOWN on the left-hand half of the unit (Section 1) to select the desired
communications channel. There are 32 possible channels available. Each unit (including the
master) MUST have a unique channel number or the system will not work correctly.
3 Now press the UP and DOWN buttons on the right-hand half of the unit to select its own,
independent communications channel. The reason for having two separate channel numbers
within one unit is that the DN9344E is seen by the system management software as
representing two individual DN9340E units, each with two channels. This allows DN9340E
and DN9344E units to be freely swapped in and out of the system without changing the
mapping between audio channels and communications channels. In other words, every
stereo pair of audio channels has a communications address, irrespective of whether it is a
DN9340E or half a DN9344E.
4 Press SETUP to confirm (unit will display password menu).
5 Press SETUP to exit.
The red alphanumeric displays are now showing the three-character name for each audio channel.
These are set from the master unit. If no names have been entered, the display will show “---”