Setup Menu: DN9340E
31
7.5. Digital Output Clock Select (Page 4)
This page selects the clock reference for the digital AES/EBU outputs. Note that the output clock
reference settings are independent of sampling frequency. The available options are:
‘System’ – the digital output is locked to the DN9340E’s
system clock. Note that this is the default setting.
‘DigSRC WCLK’ – the digital output is locked to the word
clock reference input located on the rear panel of the unit.
‘DigIn AB’ – the digital output is locked to the digital input
channel’s incoming AES/EBU bit stream. Note that this
option may only be selected when the input select is set to
‘DLck AB’, see Section 7.4.
To select the output clock source
1 Step through the Set Up menu to the Output Clock select page.
2 Use the right control knob to select the clock source.
Note To select ‘DigIn AB’, the unit’s input select must be set to be digital and
running in ‘DLck AB’ mode, see Section 7.4.
7.6. Presets lock (Page 5)
This allows the presets to be password protected to prevent unauthorised editing. The password is
six characters long.
To set a Presets lock
1 Step through the Set Up menu to the Presets lock menu
page.
2 Use the left and centre control knobs to set a password of six characters, including blank
spaces, made up of letters, numbers and/or symbols.
Important! Preliminary and subsequent blank spaces are recorded as part of the
six-character password. Therefore, if you use a short password, the characters must be
re-entered in exactly the same position to unlock the presets. To avoid confusion, either
record the blanks as part of the password or enter the word at the far left of the display.
3 Turn the right control knob clockwise to cycle to the Lock
page.
4 Press HOME (SETUP) to apply the Presets lock.
The lock state is retained after power down.