Klark Teknik DN9344E Stereo Equalizer User Manual


 
Remote Control
37
9.4. Getting started
Connect the units using the Ethernet ports as described above. Set the comms address for each
slave unit - ignore the master unit for now. It doesn't matter what addresses you use, but each unit
MUST have a unique address (two unique addresses for a DN9344E).
On a DN9340E:
1 Press and hold HOME (SETUP). The left encoder illuminates, to show that it is active.
2 Turn left encoder to select the SLAVE channel number.
3 Press HOME (SETUP) to confirm.
On a DN9344E:
1 Press SETUP.
2 Press and hold SETUP.
3 Use the UP and DOWN buttons to select the channel number for Section 1.
4 Repeat for Section 2.
5 Press SETUP to confirm (unit will display password menu).
6 Exit by pressing SETUP to step through the menu.
Setting the master unit on-line:
Once all the slaves have been set up, the master unit can be set on-line. Again, it must have a
communication channel allocated, which must not be the same as any of the slaves.
1 Press and hold HOME (SETUP). The left encoder illuminates, to show that it is active.
2 Turn left encoder to select the channel number for the master unit. Turn the centre encoder
to select MASTER mode. Turn the right encoder to select the maximum number of audio
channels in the system.
3 Press HOME (SETUP) to confirm.
The reason for setting the maximum number of audio channels is to prevent the master unit from
wasting time looking for units that are not present and trying to set them on-line, while allowing the
user to choose any channel addresses that are convenient. For example, a system including two
DN9340Es and two DN9344Es will have 12 audio channels, so set the “Max” value to 12. When the
master unit goes on-line it will search for units starting from address 1. Once it finds the correct
number of audio channels, it will stop searching.
4 The unit will now ask you to choose either to “Set All” slaves to the data contained in the
master unit (from the master unit's local copy of the slave data for each address) or to “Get
All” data from the slaves themselves. Use the centre encoder to select which one you want.
5 Press HOME (SETUP) to confirm. The unit will show a “DETECTING UNITS” page as it searches
and initialises the slaves. The system is now on-line.