To enable the Contact Closure (RELAY) mode
1 Press and hold the SETUP button to enter the SETUP menu. Note that the red alphanumeric
displays are now showing Last Recalled Memory and Communication (COMMS) mode. The
blue display mode indicator lights to emphasise this fact. The UP and DOWN buttons illuminate
to show that they are now active.
2 Use the UP and DOWN buttons to select either “RLP” or “RLU” for preset or user memory recall
modes.
Note
The left-hand (Section 1) and right-hand (Section 2) parts of the unit are entirely
independent. It is possible to use either RELAY mode on Section 1 while Section 2 is
operating in remote control mode, or vice versa. Equally, both sections can operate in either
RELAY mode if desired.
3 Press SETUP to confirm (unit will display password menu).
4 Press SETUP to exit.
Memory recalls are now performed by an external switch or relay that momentarily connects pin 9 of
the RELAY connector to one of the other pins.
Function assignments are as follows:
- Pin 1: recall Preset / User 1 on Section 1 (the left-hand unit)
- Pin 2: recall Preset / User 2 on Section 1 (the left-hand unit)
- Pin 3: recall Preset / User 3 on Section 1 (the left-hand unit)
- Pin 4: recall Preset / User 4 on Section 1 (the left-hand unit)
- Pin 5: recall Preset / User 1 on Section 2 (the right-hand unit)
- Pin 6: recall Preset / User 2 on Section 2 (the right-hand unit)
- Pin 7: recall Preset / User 3 on Section 2 (the right-hand unit)
- Pin 8: recall Preset / User 4 on Section 2 (the right-hand unit)
- Pin 9: common
Momentarily connect pin 9 to the appropriate other pin (1-8) to perform a recall.
To disable remote communications and relay operation
1 Press and hold the SETUP button to enter the SETUP menu.
2 Use the UP and DOWN buttons to select OFF for each section of the unit.
3 Press SETUP to confirm (unit will display password menu).