Kenwood TM-V708A Stereo System User Manual


 
31
6
AUTOMATIC SIMPLEX CHECK (ASC)
While using a repeater, ASC periodically monitors the
strength of a signal that you receive directly from the
other station. If the station’s signal is strong enough to
allow direct contact without a repeater, the ASC indicator
on the display begins blinking.
Press [REV] (1 s) to switch the function ON.
The ASC indicator appears when this function is ON.
While direct contact is possible, the ASC indicator blinks.
•To end this function, press [REV].
Note:
Pressing Mic [PTT] causes the ASC indicator to quit blinking.
ASC does not function if your transmit and receive frequencies
are the same (simplex operation).
ASC does not function while scanning.
Activating ASC while using Reverse switches Reverse OFF.
If you recall a memory channel or the Call channel that contains
Reverse ON status, ASC is switched OFF.
ASC causes receive audio to be momentarily intermitted every
3 seconds.
REVERSE FUNCTION
The reverse function exchanges a separate receive and
transmit frequency. So, while using a repeater, you can
manually check the strength of a signal that you receive
directly from the other station. If the station’s signal is
strong, both stations should move to a simplex frequency
to free up the repeater.
Press [REV] to switch the Reverse function ON (or
OFF).
“R” appears when this function is ON.
Note:
If pressing [REV] places the transmission frequency outside the
allowable range, then pressing Mic [PTT] causes an error beep to
sound; transmission is inhibited.
If pressing [REV] places the reception frequency outside the
allowable range, an error beep sounds and no reversal occurs.
You cannot switch Reverse ON or OFF while transmitting.
REV ON
144.725 MHz
145.325 MHz
144.725 MHz
TX: 144.725 MHz TX: 144.725 MHz
RX: 145.325 MHz RX: 145.325 MHz
TX: 144.725 MHz TX: 145.325 MHz
RX: 145.325 MHz RX: 144.725 MHz