Runco X-200i Home Theater System User Manual


 
External Control
90 Runco X-200i Series Installation/Operation Manual
PRE
L
IMINAR
Y
cal.text1
cal.text2
cal.text3
=
Up to 30 characters. The X-200i start-up screen is cus-
tomizable with three lines of text of
up to 30 characters each. This text
appears below the “CALIBRATED
FOR:” text in the logo screen. The
allowable characters are all num
-
bers, letters (uppercase and low-
ercase), spaces, and symbols
available in the ASCII code set.
3d.dlplink = ?
0 = Off
1 = On
3d.pattern = ?
0 = Off
1 = On
3D Test Patttern enable/disable
cec.enable = ?
0 = Off
1 = On
HDMI CEC enable/disable
act.source ?
Query current input source
prerr (execute)
Query the error log
hsg = ?
00 - C8 (0 - 200 decimal) for
each of the following, in this
order:
Red Hue
Yellow Hue
Green Hue
Cyan Hue
Blue Hue
Magenta Hue
Red Saturation
Yellow Saturation
Green Saturation
Cyan Saturation
Blue Saturation
Magenta Saturation
Red Level
Yellow Level
Green Level
Cyan Level
Blue Level
Magenta Level
Red Gain (White Balance)
Green Gain (White Balance)
Blue Gain (White Balance)
This command provides an alter-
native to setting the PCE Hue,
Saturation, Level and White Bal-
ance values using individual com-
mands.
It is only available when
color.gamut = 6 (PCE).
The value string is 21 bytes (42
characters) long. Each byte sets
the corresponding PCE parame-
ter; refer to the list at left.
Example: This command sets all
PCE parameters to 100 (50%):
hsg =
646464646464
646464646464
646464646464
646464
(Spaces are for readability.)
Table 6-2. Serial Commands (continued)
Operation Commands Values Notes