9.3.5 Motor (synchronous)
Press function key F12 (Software Disable) before changing motor parameters.
Motor Type: Select Synchronous Motor. If you use a linear motor or an induction motor, please
contact our support department.
Number-Name: Click the list to start uploading the motor parameter table, which is stored in the
servo amplifier. Search and select the connected motor. If your motor is not listed, please contact
our support department.
Leave all other fields unchanged.
Click OK.
If your motor has a built-in brake, click Yes,
otherwise "No".
If Software Enable is active, a warning ap
-
pears. You can proceed, but after the ampli
-
fier is restarted, you must check whether the
holding brake configuration is correct.
Click OK.
Parameters are uploaded to the amplifier's
RAM now (takes some seconds). When this is
done, you have to accept the changed config
-
uration with "Yes" or to discard the changes in
the appearing screen.
If you click "Yes", the parameters are saved in
the EEPROM and the amplifier makes a
coldstart (reset). This takes some seconds.
On the start screen, click "Feedback" button.
SERVOSTAR
®
601...620 Product Manual 79
Danaher Motion
07/2007 Setup