SSI America 601...620 Stereo Amplifier User Manual


 
8.8.2 Mains supply connection (X0)
Directly to earthed (grounded) 3~ supply, integrated EMI filter
Fusing (e.g. fusible cut-outs) provided by the user ð p.19
8.8.3 24V auxiliary supply (X4)
Electrically isolated, external 24VDC supply, e.g. with insulating transformer
Required current rating ð p.18
Integrated EMI filter for the 24V auxiliary supply
8.8.4 DC bus link (X7)
Can be connected in parallel. A patented circuit distributes the regen power among all the amplifiers
connected to the same DC bus link circuit. (Connection example ð p.72).
Only servo amplifiers with mains supply from the same mains (identical mains
supply voltage) may be connected by the DC bus link.
The sum of the rated currents for all of the servo amplifiers connected in parallel
to an SERVOSTAR 600 must not exceed 40A.
Use unshielded single cores (2.5mm²) with a max. length of 200 mm. Use shielded
cables for longer lengths.
- A.4.031.1/21,25
SERVOSTAR
®
601...620 Product Manual 49
Danaher Motion
07/2007 Electrical Installation
SERVOSTAR 600
SERVOSTAR 600