4 Handling
4.1 Transport
l
Only by qualified personnel in the manufacturer’s original recyclable packaging
l
Avoid shocks
l
Temperature –25 to +70°C (-13...158°F), max. 20K/hr rate of change
l
Humidity max. 95% relative humidity, no condensation
l
The servo amplifiers contain electrostatically sensitive components which can be da
-
maged by incorrect handling. Discharge yourself before touching the servo amplifier.
Avoid contact with highly insulating materials (artificial fabrics, plastic films etc.). Place
the servo amplifier on a conductive surface.
l
If the packaging is damaged, check the unit for visible damage. In this case, inform the shipper
and the manufacturer.
4.2 Packaging
l
Cardboard box, can be recycled
l
Dimensions: SERVOSTAR 601...610 (HxWxD) 125x415x350 mm
SERVOSTAR 614 / 620 (HxWxD) 170x415x350 mm
l
Labeling : nameplate outside at the box
4.3 Storage
l
Storage only in the manufacturer’s original recyclable packaging
l
Max. stacking height 8 cartons
l
Storage temperature -25 to +55°C, max. rate of change 20°C / hour
l
Storage humidity 5 ... 95% relative humidity, no condensation
l
Storage duration Less than 1 year without restriction.
More than 1 year: capacitors must be re-formed before setting up and operating the servo am
-
plifier. To do this, remove all electrical connections and apply single-phase 230V AC for about
30 minutes to the terminals L1 / L2.
4.4 Maintenance
The instruments do not require any maintenance, opening the instruments invalidates the warranty.
Cleaning : — if the casing is dirty: clean with Isopropanol or similar
do not immerse or spray
— if there is dirt inside the unit it must be cleaned by the manufacturer
— dirty protective grill on fan must be cleaned with a dry brush
4.5 Disposal
In accordance to the WEEE-2002/96/EG-Guidelines we take old devices and accessories back for
professional disposal, if the transport costs are taken over by the sender. Send the devices to:
Danaher Motion GmbH
Wacholderstr. 40-42
D-40489 Düsseldorf