Regen circuit: technical data SERVOSTAR
Supply
voltage
Rated data DIM 601 - 603 606 - 620
3 x 230 V
Upper switch-on level of regen circuit V 400 - 430
Switch-off level of regen circuit V 380 - 410
Overvoltage F02 V 450
Continuous power of regen circuit (R
Bint
) W 80 200
Continuous power of regen circuit (R
Bext
) max. kW 0.25 0.75
Pulse power, internal (R
Bint
max. 1s) kW 2.5 5
Pulse power, external (R
Bext
max. 1s) kW 5
External regen resistor
W
33
3 x 400 V
Upper switch-on level of regen circuit V 720 - 750
Switch-off level of regen circuit V 680 - 710
Overvoltage F02 V 800
Continuous power of regen circuit (R
Bint
) W 80 200
Continuous power of regen circuit (R
Bext
) max. kW 0.4 1.2
Pulse power, internal (R
Bint
max. 1s) kW 8 16
Pulse power, external (R
Bext
max. 1s) kW 16
External regen resistor
W
33
3 x 480 V
Upper switch-on level of regen circuit V 840 - 870
Switch-off level of regen circuit V 800 - 830
Overvoltage F02 V 900
Continuous power of regen circuit (R
Bint
) W 80 200
Continuous power of regen circuit (R
Bext
) max. kW 0.5 1.5
Pulse power, internal (R
Bint
max. 1s) kW 10.5 21
Pulse power, external (R
Bext
max. 1s) kW 21
External regen resistor
W
33
Suitable external regen resistors can be found in our accessories manual.
SERVOSTAR
®
601...620 Product Manual 23
Danaher Motion
07/2007 Technical description