John Deere OMPC20964 Radio User Manual


 
Troubleshooting and Diagnostics
OUO6050,0002238 –19–14NOV06–2/2
SPN.FMI SPN Name Tractor Warning Light
FMI Description Level 1 Text
Rollover Sensor (956)
Data Valid but Above Normal Operating Range - Moderately Severe Level Service Alert
956.16 (16) Roll Accelerometer out of range
RTK base station location (524257) No Lamp
524257.1 Special Instructions (14) RTK Base Station Position Survey in progress
RTK base station location (524257)
Data Valid but Above Normal Operating Range - Moderately Severe Level Service Alert
524257.2 (16) RTK Base Station relocation
RTK Rover relative distance (524209)
Data Valid but Above Normal Operating Range - Moderately Severe Level No Lamp
524209.2 (16) RTK Rover too far from Base Station
Source Address 146 (2146) Info
2146.13 Out of Calibration (13) TCM not calibrated
Source Address 146 (2146) Service Alert
2146.14 Special Instructions (14) Temp sensor out of range
Yaw Gyro (523309) Service Alert
523309.7 Mechanical System not Responding or Out of Adjustment (7) Yaw Gyro not responding
Yaw Gyro (523309)
Data Valid but Above Normal Operating Range - Moderately Severe Level Service Alert
523309.2 (16) Yaw Gyro out of range
40-12
121907
PN=148