Polycom C12 Speaker System User Manual


 
Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 34
phantom 48 V Phantom Power
Description
Enables or disable phantom power on mic inputs. Setting phantom to 1 enables
phantom power, while setting it to 0 disables phantom power.
Examples
safety_mute Safety Mute
Description
This parameter sets the status of the safety mute. If safety mute is enabled (1),
all line outputs of all the devices are muted.
Examples
Argument Argument value
Channel Type Virtual Channel
Value Type Boolean
Read/Write Mode Read/Write
Phys Chans Conferencing Mic/Line Input, Sound Reinforcement Mic/Line
Input
Virt Chans Mono, Stereo
Default 0
Command Response Description
set phantom "Table
Mic 1" 1
val phantom "Table
Mic 1" 1
Enables the 48V phantom power supply for the input channel
"Table Mic 1".
Argument Argument value
Channel Type Global System
Value Type Boolean
Read/Write Mode Read/Write
Default 0
Command Response Description
set safety_mute 1 val safety_mute 1 Enables the safety_mute for a SoundStructure system.
set safety_mute 0 val safety_mute 0 Turns off the safety_mute for a SoundStructure system.