Polycom C12 Speaker System User Manual


 
Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
7 - 28
Once entries have been moved, select “Save Selected” to save the new execu-
tion order.
Running Presets
Both full and partial presets may be executed when in SoundStructure Studio
by left clicking the preset to execute and then clicking Run Preset.
A control system would execute the preset with the command action run as in
the following example:
run “Power-On”
Full Presets
When a full preset is executed all the outputs of the system are muted during
the execution of the preset and then unmuted after the full preset finishes
executing.
No command acknowledgements are generated when a full preset is executed.
If there are parameters that a control system needs to know the value of, these
parameters should be queried after the execution of the preset.
Partial Presets
Partial presets will generate command acknowledgements for all parameters
that are changed during the execution of the preset. The outputs of the system
are not muted during a partial preset unless the designer explicitly inserts
commands to mute the outputs of the system during the partial preset.