Paradise 205486 REV F Stereo Amplifier User Manual


 
54 205486 REV F Operations Manual, HPA2, Compact Outdoor SSPA
Once reliable communication has been established between each amplifier and the computer,
the Redundancy Control Panel can be displayed. From the M&C program’s main window,
choose “Action” “Internal Redundant System” “1:1 Compact Outdoor SSPA System”.
See Figure 7-12.
The Redundant Control Panel window will then be displayed as in Figure 7-13. Note that once
the Redundant Control Panel is enabled, the Main Menu on the M&C program changes.
The Control Panel must be configured by selecting “Set Redundancy System” and choosing
an amplifier for SSPA 1 and SSPA 2. Either amplifier may be designated as SSPA 1 or
SSPA 2. Each amplifier is identified by its ID number. The ID number is a fixed number and
cannot be changed. It is a unique encoded value determined by the particular amplifier’s
model number and serial number. If the ID number is forgotten, refer to the System Watcher
window. This window continuously displays which amplifier, by ID number, is connected to
each specific COM port. After the Control Panel has been configured the display will change
to the view shown in Figure 7-14.
Figure 7-12: Paradise Datacom Universal M&C, Add Unit Menu Tree
Figure 7-13: Add 1:1 Redundant System Window