Panasonic WJ-DR200 Stereo Receiver User Manual


 
V OH = 11 - 13 V (4 700 )
V OL = 0 - 0.6 V (3.0 mA max.)
V OH = 5±0.5 V (200 )
V OL = 0 - 0.6 V (3.0 mA max.)
Alarm
Recover
Output
-47-
General
Power Source: 120 V AC, 60 Hz
Power Consumption: 38 W
Ambient Operating Temperature: +5°C - +40°C (41°F - 104°F)
Ambient Operating Humidity: Less than 90 %
Dimensions: 420 (W) x 88 (H) x 350 (D) mm
16-9/16” (W) x 3-7/16” (H) x 13-3/4” (D)
Weight: 7 kg (15.4 lbs.)
Input and Output
Video Input A: 1.0 V[p-p]/75 NTSC Composite Video Signal
with 75 Automatic Termination/Looping through (x1)
Y Signal; 0.714 V[p-p], C Signal; 0.286 V[p-p]/75 S-Video Signal (x1)
Video Input B: 1.0 V[p-p]/75 NTSC Composite Video Signal
with 75 Automatic Termination/Looping through (x1)
Video Output: 1.0 V[p-p]/75 NTSC Composite Video Signal (x1)
Y Signal; 0.714 V[p-p], C Signal; 0.286 V[p-p]/75 S-Video Signal (x1)
Audio Input: 47 kunbalanced, RCA standard jack, 11 kHz sampling
Audio Output: 600 unbalanced, RCA standard jack
Camera Switching Output: 1 circuit, RCA standard jack
Terminal Board: Sensor Input: Pulse width 100 ms or more, Normally open or normally closed
selectable
Alarm Input: Pulse width 100 ms or more, Normally open or normally colosed
selectable
Alarm Reset Input: Pulse width 100 ms or more, Low active
Series Record Input: 1 circuit
Time Adjustment Input: Pulse width 100 ms or more, Low active
Alarm Output: Switched by alarm output level selector*
1
Alarm Recover Output: Switched by alarm output level selector, Pulse width 100
ms*
1
LED Monitor Output: 1 circuit (ALARM REC, REC, DISC), 30 V DC 50 mA max.
Buzzer Output: 30 V DC 50 mA max.
System Error Output: 30V DC 50 mA max.
Thermal Error Output: 30 V DC 50 mA max.
Time Adjustment Output: Pulse width 1 s, 30V DC 50 mA max.
Series Record Output: 30 V DC 50 mA max.
Serial Control Port: Baud Rate; 2 400 - 115 200 bps, Data Bit: 8, Parity Check: None, Start Bit: 1, Stop
Bit: 1, (25-pin D-sub Connector)
Parallel Control: (25-pin D-sub Connector)
*
1
Alarm Output Level Selector [H]
SPECIFICATIONS
Weight and dimensions shown are approximate.
Specifications are subject to change without notice.
Alarm
Output
V OL
V OH
Alarm
Alarm Output Level Selector [L], 30 V DC 50 mA max.