-22-
2. Select either pattern by pressing the or but-
ton.
SAME AS ALARM: Same recording pattern as
for alarm activation
DIFF FROM ALARM: Different recording pattern
than for alarm activation
The default setting is SAME AS ALARM.
3. If you select DIFF FROM ALARM in step 2 above,
you need to change the following parameters.
• Pre/Post-Frames
This item lets you select the number of pre and
post-frames recorded when there is sensor input
from the SENSOR IN terminal.
The maximum number of pre and post-frames is set
with the PRE/POST FRAMES parameter above.
1. Move the cursor to the PRE/POST FRAMES
parameter in the MULTI SHOT menu by press-
ing the or button.
2. Select the number of pre and post-frames to be
recorded by pressing the or button.
• Post-Frame Recording Pattern
This item is available only if the CAMERA INPUT
parameter in the VIDEO INPUT menu is set to A+B
(CAMERA ID OFF).
It lets you select recording of pre and post-frames
from input A and/or B when there is sensor input
from the SENSOR IN terminal.
1. Move the cursor to the POST REC PATTERN para-
meter in the MULTI SHOT menu by pressing the
or button.
2. Select the desired recording input for post-frames
by pressing the or button.
AA: Records input A for post-frames.
BB: Records input B for post-frames.
AB: Records input A and B for post-frames.
2. Time Lapse Recording Menu
This menu lets you set up the details for Time Lapse
Recording.
Note: Manual Alarm Recording, Record Partition and
Auto Start are not available in MODE 2.
1. Move the cursor to the CAPTURE MODE parameter
in the REC MODE menu by pressing the or
button.
● Pre/Post Frames
This item lets you specify the number of pre-frames.
A pre-frame is a frame recorded during standby for
manual recording or prior to input of the alarm signal in
alarm recording.
A post-frame is a frame recorded after the REC button
was pressed in manual recording or after input of the
alarm signal in alarm recording.
1. Move the cursor to the PRE/POST FRAMES para-
meter in the MULTI SHOT menu by pressing the
or button.
2. Select the desired number of pre-frames by press-
ing the
or
button.
Subtracting the number of pre-frames from this total
gives you the number of recorded post-frames.
The default setting is 0.
● Recording Pattern
When the CAMERA INPUT parameter in the VIDEO
INPUT menu is set to A+B (CAMERA ID OFF), this item
lets you select recording of pre and post-frames from
input A and/or B.
1. Move the cursor to the REC PATTERN parameter in
the MULTI SHOT menu by pressing the or
button.
2. Select the desired recording input by pressing the
or button as shown below.
Pre Frame
Quantity
Zero
AA
AB
BB
–
–
–
A
A and B
B
AA/BB
AA/AB
BB/AA
BB/AB
AB/AA
AB/BB
AB/AB
More then
one
A
A
B
B
A and B
A and B
A and B
B
A and B
A
A and B
A
B
A and B
Pre Frame
Recorded
Post Frame
Recorded
Parameter
● Sensor Recording
This item lets you select whether to record sensor input
from the SENSOR IN terminal on the rear of the Disc
Recorder according to the same pattern as set for alarm
recording or according to a different pattern.
1. Move the cursor to the SENSOR REC parameter in
the MULTI SHOT menu by pressing the or
button.