5 - 4
5. PARAMETERS
(2) Details list
Classifi-
cation
No. Symbol Name and Function
Initial
Value
Unit
Setting
Range
1 *AMS Amplifier setting
Used to select the absolute position detection.
Absolute position detection selection
0: Invalid (Used in incremental system.)
1: Valid (Used in absolute position
detection system.)
0 00
0000 Refer to
name
and
function
column.
Regenerative resistor
Used to select the regenerative option used.
Regenerative selection option
00: Regenerative option is not used with 7kW or
less servo amplifier (The built-in regenerative
resistor is used. However, the MR-J2S-10B
does not have a built-in regenerative resistor
and therefore cannot use it.)
Supplied regenerative resistors or regenerative
option is used with 11k to 22kW amplifier
01: FR-RC, FR-BU2, FR-CV
05: MR-RB32
08: MR-RB30
09: MR-RB50 (Cooling fan is required)
0B: MR-RB31
0C: MR-RB51 (Cooling fan is required)
0E: When regenerative resistors or regenerative
option supplied to 11k to 22kW are cooled by
cooling fans to increase capability
10: MR-RB032
11: MR-RB12
The MR-RB65, 66 and 67 are regenerative options
that have encased the GRZG400-2 ,
GRZG400-1 and GRZG400-0.8 , respectively.
When using any of these regenerative options,
make the same parameter setting as when using
the GRZG400-2 , GRZG400-1 or
GRZG400-0.8 (supplied regenerative resistors or
regenerative option is used with 11k to 22kW
servo amplifier).
00
Select the external dynamic brake.
0: Invalid
1: Valid
Select "1" when using the external dynamic brake
with the MR-J2S-11KB to 22KB.
POINT
Wrong setting may cause the regenerative option
to burn.
If the regenerative option selected is not for use
with the servo amplifier, parameter error (37)
occurs.
2*REG 0000 Refer to
name
and
function
column.
3 0080
4 0000
Basic parameters
5
For manufacturer setting by servo system controller
Automatically set from the servo system controller
1