Sony MDS-PC3 Stereo System User Manual


 
51
Additional Information
Self-Diagnosis Function
The decks self-diagnosis function automatically checks the condition of the MD deck when an error
occurs, then issues a three-digit code and an error message on the display. If the code and message
alternate, find them in the following table and perform the indicated countermeasure. Should the problem
persist, consult your nearest Sony dealer.
Three-digit code/Message Cause/Remedy
C11/Protected The inserted MD is record-protected.
, Take out the MD and close the record-protect slot (page 13).
C12/Cannot Copy An attempt was made to play a disc that is not compatible with this deck
(MD data disc, etc.).
, Replace the disc.
C13/Rec Error The recording was not made properly.
, Set the deck in a stable surface, and repeat the recording procedure.
The inserted MD is dirty (with smudges, fingerprints, etc.), scratched, or
substandard in quality.
, Replace the disc and repeat the recording procedure.
C13/Read Error The deck could not read the TOC on the MD properly.
, Take out the MD and insert it again.
C14/Toc Error The deck could not read the TOC on the MD properly.
, Insert another disc.
, If possible, erase all the tracks on the MD (page 29).
C41/Cannot Copy The digitally dubbed material cannot be recorded digitally (page 11).
C71/Din Unlock The sporadic appearance of this message is caused by the digital signal being
recorded. This will not affect the recording.
While recording from a digital component connected through the DIGITAL
(OPTICAL) IN connector, the digital connecting cable was unplugged or the
digital component turned off.
, Connect the cable or turn the digital component back on.
E0001/MEMORY NG There is an error in the internal data that the deck needs in order to operate.
, Consult your nearest Sony dealer.
E0101/LASER NG There is a problem with the optical pickup.
, Consult your nearest Sony dealer.