Barco R9010300 Home Theater System User Manual


 
2. Installation Guidelines
Metric Formulas (meter) Inch formulas (inch)
TLD HB (2.8 -
5)
Wide
PD = 2.83 x SW - 0.14 PD = 2.83 x SW - 5.51
Tele
PD = 5.15 x SW - 0.35 PD = 5.15 x SW + 13.78
TLD HB (5 - 8)
Wide
PD = 4.94 x SW + 0.01 PD = 4.94 x SW + 0.39
Tele
PD = 8.23 x SW - 0.26 PD = 8.23 x SW - 10.24
2.3.3 Lens installation
The default lens is standard mounted on the projector when it arrives on your location.
How to replace with another lens?
Follow the next procedure:
1. Move the handle (A) of the lens anchor system to the left and take out the lens.
2. Take the new lens assembly out of its packing material and remove the lens caps on both sides.
3. Push the lens, motors at the top, in the lens
block gap horizontally, lining up the motor connector on the lens with the connector
on the lens block (B). (image 2-3)
Caution: On a table m ounted projector, hold the projector when pushing the lens into the lens block to avoid sliding off from
the table.
4. Move the handle (A) of the lens anchor system to the right (front view, table mount) to lock the lens.
Image 2-3
2.3.4 Cleaning the lens
To minimize the pos
sibility of damage to optical coatings, or scratches to lens surfaces, we have developed
recommendations for clean. FIRST, we recommend you try to remove any material from the lens by blowing
it off with clean, dry deionized air. DO NOT use any liquid to clean the lenses.
Necessary tools
Toraysee
TM
cloth (delivered together with the lens kit). Order number : R379058.
Howtocleanthelens?
Proceed as follow :
1. Always wipe lenses with a CLEAN Toraysee
TM
cloth.
2. Always wipe lenses in a single direction.
Warning: Do not wipe back and forwards across the lens surface as this tends to grind dirt into the coating.
3. Do not leave clean
ing cloth in either an open room or lab coat pocket, as doing so can contaminate the cloth.
4. If smears occur when cleaning lenses, replace the cloth. Smears are the first indication of a dirty cloth.
16
R5976817 RLM H5 02/06/2006