11. Lamps Menu
Image 11-4
When switching from the dual mode to the single mode the lamp with the longest runtime is switched off.
If the runtimes are equal (if the projector has always been operated in dual mode) then lamp 1 is switched out.
When switching to single mode, returning to the dual mode will not be possible in the first 60 seconds, Dual
in the menu is greyed out and LED3 is flickering, thereby preventing hot restrike which may dama
ge the lamp.
11.4 Economic ON/OFF
What can be done?
The lamp power can be reduced to save the lamp.
How to switch to an economic mode ?
1. Press MENU to activate the menu bar.
2. Press to select the Lamps item. (image 11-5)
3. Press to pull down the Lamps menu.
4. Use or to select Economic.
5. Press to select the On or Off item.
On
Economic mode is switched on
Off Economic mode is switched off
6. Press ENTER to confirm.
Image 11-5
11.5 Runtime warning
What can be done ?
When the lam
p has reached a certain predetermined runtime, a warning message will be displayed on the screen. The lamp runtime
warning can be set in a range from 30 to 200 hours. The runtime warning is displayed by default at 30 hours before end of lamp
lifetime.
How to set the lamp runtime warning?
1. Press MENU to activate the menu bar.
2. Press to
select the Lamp item. (image 11-6)
3. Press to pull down the Lamps menu.
R5976817 RLM H5 02/06/2006