HP (Hewlett-Packard) SSL1016 Cassette Player User Manual


 
Troubleshooting
138 SSL1016 Tape Autoloader Reference Guide
Diagnostic Tests
Table 15 lists the diagnostic tests.
Table 15: Diagnostic Tests
Test Description
Halt Cancels any currently running test.
Self
Checks the ability of the picker to properly rotate and
translate.
Verifies that installed magazines function correctly.
Health
Verifies picker movement.
Verifies magazine movement.
Updates inventory.
Verifies ability to move cartridge to and from each
magazine element.
Verifies drive communication and ability to move a
cartridge to and from the drive.
Verifies that a cartridge can be moved to and from the
mail slot.
Picker
Performs a full picker translation calibration.
Performs a full picker rotation calibration.
Magazine
Performs left and right magazine calibration.
Verifies successful slot movement.
Inventory Takes a snapshot of the current labels recorded for each
cartridge present, then performs and inventory and compares
the new results to the snapshot.
Drive Read/Write Performs a write of two full tracks of data followed by a read
and if the drive is capable performs a compare on the data.
Verifies the write/read statistics to determine if there is a write
or read problem with the drive.
Caution: Running this test may overwrite existing data on the
tape. Do not use a tape containing current or critical data.