Dynacord DPM 4000 Stereo System User Manual


 
DEVICE DESCRIPTIONS
PROANNOUNCE System User Handbook 1.1 5-53
· LED-meter instrument; indication in the range of –13 dB to 0 dB and CLIP
· Mains voltage selector switch 115/230 V AC
· Active, temperature-controlled fans
· Modules for pilot tone surveillance and ground fault surveillance according to DIN VDE 0800 (optionally
available)
The appliance allows connecting four balanced XLR-type input lines as well as connection to the remote control bus of
the DPM 4000 (RS-485). Prior to connecting the amplifier to the operating voltage, the unit’s address has to be set
using the switches “A” and “B” (A=low value part).
For detailed information on the four-channel power amplifier DPA 4411, please refer to the owner’s manual 356810.
The following remote functions are available:
Control:
· Level controls, Mute of all channels
· Monitor activation (Input / Output) for all channels
· Mains operation ON/OFF
· Battery operation ON/OFF
· Pilot tone ON/OFF (optionally available)
Messages:
· Output level (all channels)
· Pilot tone detection (all channels)
· Ground fault detection (all channels)
· Thermal overload amplifier / mains transformer
· Configuration
· Measured values of current and voltage at the power outputs
· Extension-kits