7 Connections to commercial equipment.
(Before connecting this unit with other units please
remove the power connection to this unit.)
Balanced analog connections
Using the balanced connections on this unit reduces the
possibility of noise and interference from other devices, this
method of interconnection is normally used in broadcast and
recording installations.
For connection to the balanced input and output sockets of
this unit, use XLR type connectors (not supplied) types XLR-
3-11C and XLR-3-12C.
A Connect the balanced output of this unit to the balanced
input of a mixer, amplifier or other device. Connect the
balanced input of this unit to the balanced output of a mixer
or other device. Ensure that the left and right channels are
matched left to left and right to right.
Balanced AES/EBU digital connection
This connection adopts the AES/EBU professional digital
interconnection standard as used by studios, broadcasters
etc., use XLR type connectors (not supplied) type XLR-3-12C.
B Connect the AES/EBU digital input socket on the unit to
the AES/EBU digital output from a mixer or other device.
C About XLR connection cables.
These connections require a three pin XLR type cable (not
supplied) for balanced interfacing to the unit. These cables
adopt the European standard system for polarity, pin 2 hot +
pin 3 cold – with pin 1 being the ground connection. Please
be careful to ensure that the polarity of the connection is
correct to the devices to which it is interfaced (American
polarity uses pin 3 hot + and pin 2 cold – and interfacing with
connectors wired this way would cause phase reversal or
even loss of signal).
D After completing connections with other equipment
please ensure the power connection to the unit is
reconnected.
CONNECTION WITH OTHER EQUIPMENT
Press here when removing.
Appuyez ici pour retirer.
Presione aquí para desconectar.
Align here.
Alignez ici.
Alinee aquí.
A
XLR connection method
Connexion XLR
Método de conexión XLR
B
IN
1
3
2
PUSH
European system
Système européen
Sistema europeo
C
1: GND, 2: HOT, 3: COLD
1: MASSE, 2: CHAUD, 3: FROID
1: MASA, 2: CONECTADA,
3: DESCONECTADA
CDR-850
OUT
132
IN
Press here when removing.
Appuyez ici pour retirer.
Presione aquí para desconectar.
Align here.
Alignez ici.
Alinee aquí.
OUT
C
PUSH
R L
LINE IN LINE OUT
DIGITAL IN
DIGITAL IN
OPTICALCOAXIAL
S/PDIF
AES
/EBU
RL RL
OPTICAL
DIGITAL OUT
COAXIAL
S/PDIF
PUSH
PUSH
BALANCED IN BALANCED OUT
PUSH
RL
SIGNAL
GND
AC IN
PARALLEL
REMOTE
AES
/EBU
DIGITAL
OUT
RLRL
PUSH
BALANCED IN BALANCED OUT
PUSH
RL RL
PUSH
BALANCED IN BALANCED OUT
PUSH
DIGITAL IN
AES
/EBU
PUSH
L
R
L
R
D