Sonance C4630 SE Stereo System User Manual


 
55
C4630 SE HOME AUDIO SYSTEM
SERIAL CONTROL
Problem Solution
No RS-232 communication with an a) Is the external device ON?
external device b) Is the external device connected with the proper RS-232 cable? Check the
configuration of the external device’s RS-232 port. The C4630 SE’s RS-232
pin configuration is:
PPiinn 22 == RReecceeiivvee ((RRxx)),, ppiinn 33 == TTrraannssmmiitt ((TTxx)),, PPiinn 55 == GGrroouunndd ((GGnndd))
.
c) Are the ‘baud rate’ and ‘format’ of the external device properly configured?
See page 40.
d) Is the external device properly configured to send/receive?
e) Are the ASCII text serial commands programmed in Sonance Control
Manager correct? See page 40.
f) If using Hex commands, be sure the Macro Editor screen’s H
EX MODE button
is pressed before inputting the Hex command (see page 40).
g) If the C4630 SE is being serial-controlled by the external device, make sure
that all C4630 SE macros are purged of all RS-232 commands (see page 50).
PROGRAM MANAGER
Problem Solution
The USB connection gives a a) Disconnect and re-connect the USB cable from the C4630 SE and/or the
Windows error: D
EVICE NOT DETECTED computer.
b) Re-install the USB driver in the computer.
c) Confirm that you have made the proper computer Com Port selection and
connection.
d) Unplug the USB cable from the C4630 SE, select D
OWNLOAD TO DEVICE on the
Sonance Control Manager and then re-connect the USB cable to the C4630 SE.