6. Press the removable connector into the corresponding zone SPEAKER OUT connector on
the controller until it locks into place (see
Figure 6
).
• The removable connectors will only fit one way on the controller.
Zone Line Output Connections
In addition to Speaker Output connectors, each zone on the C4630 SE also has a set of
Line Output jacks (see
Figure 6)
. The Zone Line Outputs let you connect high-power
amplifiers to individual zones that require more power than the C4630 SE’s built-in
30 Watt/ch amplifier can provide, or expand a zone into sub-zones by using a multi-
channel amplifier.
Line Output Fixed/Variable Switch
Each zone Line Output has a push-button switch that toggles the Line Output between
V
ARIABLE (OUT) and FIXED (IN). (See
Figure 6
.) The VARIABLE setting allows zone keypad
and remote controllers to control the level of the Line Outputs. In the F
IXED setting the Line
Output level cannot be varied. Keypad and remote control M
UTE controls function in
both
the FIXED and VARIABLE settings.
IImmppoorrttaanntt::
DDoo
nnoott
ppuusshh
tthhee
LLiinnee
OOuuttppuutt FF
IXED
//VV
ARIABLE
sswwiittcchh
wwhhiillee
tthhee
CC44663300
SSEE
iiss
ooppeerraattiinngg..
DDooiinngg
ssoo
ccaann
pprroodduuccee
hhiigghh
oouuttppuutt
lleevve
ellss
tthhaatt
ccaann
ddaammaaggee
tthhee
CC44663300
SSEE,,
tthhee
ccoonnnneecctteedd
aammpplliiffiieerr
oorr
tthhee
ssppeeaakkeerrss..
NOTE: Setting a zone’s output to Fixed disables the following Sonance Control Manager Zone Setup
features for that zone: Default Volume, Maximum Volume, Page Volume, Balance, Bass, Treble. See
pages 29 and 30.
Connecting a High-Power Amplifier in a Zone
1. Set the zone’s Variable/Fixed Output switch to the VARIABLE (OUT) position.
2. Connect a stereo RCA cable from the appropriate Zone Line Outputs on the C4630 SE to the high-power amplifier’s
input connectors (see
Figure 7
, on page 14). The VARIABLE setting allows the zone’s volume to be controlled by the C4630
SE via a keypad or a properly-programmed IR remote.
Using a Multi-Channel Amplifier for Sub-Zone Expansion
1. Set the zone’s Variable/Fixed Output switch to the FIXED (IN) position.
2. Connect a stereo RCA cable from the appropriate Zone Line Outputs on the C4630 SE to the multi-channel amplifier’s
Bus input connectors (see
Figure 8
, on page 14). For example, an 8-channel amplifier like the Sonamp 875D SE will
let you put four speaker pairs in the zone. The F
IXED output setting allows the C4630 SE’s Mute function to mute all
four sub-zones. Volume for each pair of speakers in each sub-zone is controlled by an in-wall volume control.
3. Connect the Control Out on the C4630 SE to the External Control input on the sub-zone amplifier (if available) to
automatically power-up the external amp when any zone on the C4630 SE is ON.
NOTE: The C4630 SE can also turn connected amplifiers ON and OFF via serial control. See page 40.
VARIABLE FIXED
OUT
IN
L
R
L
R
LINE OUT
SPEAKER OUT
8 Ω NOMINAL IMPEDANCE
34
L+
L-
R-
R+
L+
L-
R-
R+
Figure 6:
Zone Line Outputs, Speaker
Outputs and Line Output
Fixed/Variable Switches