Lucent Technologies 585-210-940 Speaker User Manual


 
Troubleshooting CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems
Error messages 88
Error messages 4
The table that follows lists and explains error messages you can receive
related to
Solstice DiskSuite
and disk mirroring. The messages are
presented in alphabetical order, ignoring special characters and
replacement strings. (For example, you would find the message
filename
restored”
in alphabetical order by the word
restored
.)
Error Messages
Message:
All data on cms filesystems will be removed
and filesystems will be unmirrored, are
you sure?
Explanation: Standard warning message for
olds -mirrored
-cleanup
command.
Response: Always use an
olds -mirrored -cleanup
with
caution, keeping in mind that a backup will be needed to
recover any CMS data in the
/cms
filesystem. Use the
command only to set up your system from scratch.
Message:
Attempt an operation on a submirror that
has erred components.
Explanation: Component needs maintenance before the operation can
be carried out.
Response: 1. Execute a
metastat
command.
2. Examine the output for the
Invoke
line and execute
the command named in that line. For example:
# metareplace -e d13 c0t0d0s0
3. Reboot system.
Message:
CDROM must not be present, remove CD
Explanation: In order for the command to execute, the CDROM drive
must be empty.
Response: 1. Enter the command:
eject cdrom
2. Remove the CD from the drive tray.
3. Close the drive tray.