Lucent Technologies 585-210-940 Speaker User Manual


 
Troubleshooting CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems
The system fails to recognize all disk drives 82
The system fails to recognize all disk drives 4
If the system should fail to recognize all disk drives, do the following:
1. Reboot the system by entering the following command:
The system reboots and displays the
ok
prompt:
2. Turn off the system unit.
3. Turn off all external devices starting with the system monitor and
working toward the device farthest from the system unit.
4. Check all disk drive connections to make sure they are secure.
5. Turn on the power to the system components in the opposite order
in which you powered them off. Power on the SCSI devices first,
beginning with the device at the end of the chain and working your
way toward the system unit. Then power on other devices, again
working your way toward the system unit.
Finally, power on the system unit itself and the system monitor.
When you power on the system unit, the system begins to boot.
Interrupt the boot by pressing Stop-A.
The system displays the
ok
prompt.
6. To verify that the system sees all the disk devices, including any new
drives, enter one of the following commands:
If you receive a “
This command may hang the system
....”
message, respond with the following steps:
a. Enter:
n
(to prevent the probe from continuing).
b. Enter:
setenv auto-boot? false
(to prevent a reboot when you do the next command)
c. Enter:
reset-all
(it may take a minute to complete).
Now repeat the
probe-scsi-all
or
probe-fcal-all
.
The program responds to the probe as shown below. The specific
response, of course, differs depending on the platform.
# /usr/sbin/shutdown -y -g0 -i0
ok probe-scsi-all
ok probe-fcal-all
Enterprise
3000
Enterprise
3500