Installing Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems
Factory installation procedures for disk mirroring 28
Factory installation procedures for disk mirroring 2
This section describes how a mirrored system is installed on a new
Sun
Enterprise
3xxx computer in the factory. You may use these instructions
in the field to bring an existing system up to factory specifications.
Step 1: Install the
hardware
2
Install hardware components as required. For details and instructions,
see the appropriate Lucent hardware installation document and the
Sun
Microsystems
documents shipped with your machine.
Step 2: Install the
operating system
2
Install the
Solaris
operating system. Partitioning the disks will be part of
that process.
To install the
Solaris
operating system, follow the instructions in the
CentreVu CMS R3V8 Software Installation and Setup
(585-210-941)
document, with the following exception:
●
Use the
Disks
and
Partitioning
tables below to determine disk
partitioning details.
Disks
shows which disks are boot disks and
which are not;
Partitioning
shows partitioning details.
Disks
Disk
Enterprise
3000
Device Names
Enterprise
3500
Device Names
boot disk 1 c0t0d0 c0t0d0
boot disk 2 c0t1d0
a
aTrue for factory-installed disk mirroring. Unlikely to be true
for systems upgraded to disk mirroring in the field.
c1t4d0
other disks c0t2d0
c0t3d0
c0t10d0
c0t11d0
c0t12d0
c0t13d0
c0t14d0
c0t15d0
c0t1d0
c0t2d0
c0t3d0
c1t5d0
c1t6d0
c1d7d0