Lucent Technologies 585-210-940 Speaker User Manual


 
Installing Mirrored Systems CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems
Factory installation procedures for disk mirroring 31
5. Check the disks:
6. Create system files for the
Solstice DiskSuite
software:
7. Make sure all the disk drives on your system have been recognized.
To do that, read the file
/olds/md.tab.new
into an editor and locate
the
#/cms
section. It should reflect the precise number of disk drives
on your system. The following example shows a total of four disk
drives on the system, two in d19 and two in d20:
If there is a discrepancy between what the system should have
recognized and what it
did
recognize, complete the procedure in
“The system fails to recognize all disk drives” on page 82, and then
return to item 5.
# olds -mirrored -check_disks
number of external scsi controllers with disks
is = 0
number of disks is = 4
...
disk:c0t0d0 is partitioned ok
disk:c0t1d0 is partitioned ok
disk:c0t2d0 is partitioned ok
disk:c0t3d0 is partitioned ok
Success, checking disks for mirroring.
#
# olds -mirrored -mk_files
#
.
.
.
#metaroot
d11 1 1 c0t0d0s0
d12 1 1 c0t2d0s0
d13 -m d11
#/cms
d19 2 1 /dev/rdsk/c0t0d0s3 1 /dev/rdsk/c0t1d0s1
d20 2 1 /dev/rdsk/c0t2d0s3 1 /dev/rdsk/c0t3d0s1
d21 -m d19
#metaswap
d15 1 1 c0t0d0s4
d16 1 1 c0t2d0s4
d17 -m d15