Troubleshooting CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems
Error messages 96
Message: Usage: olds -mirrored -check_disks|
-mirrored -mk_files|-metadbs|-cleanup|
-mirrored -setup [disk name]
Explanation: You have mistyped a command.
Response: Retry the command. See Chapter 3 for information about
olds
command syntax.
Message:
Warning: inode blocks/cyl group (230 >=
data blocks (135) in lost cylinder group.
This implies 2160 sector(s) cannot be
allocated.
Explanation: Some sectors will not be used by the filesystem. This is
just a warning; the filesystem should be fine.
Message:
Warning: script does not support this
configuration, configure manually
Explanation: The olds script is supported only with the hardware
described in Chapter 1.
Response: Verify that you have appropriate hardware. If you need
extra disks for purposes other than mirroring CMS, you
may attach them after disk mirroring has been installed
and has been verified to be running correctly.
Message:
x25netd: failed to open
driver /dev/hih
x
(Bad file number [
n
])
Response: Enter the following command:
/cms/toolsbin/lnSBusdev
Message:
You must be root in order to run this
command.
Explanation: You are not logged in as the
root
user, but you must be in
order to run the command.
Response: Log in as
root
and retry the command.
Message:
You need to have at least one disk setup,
before attaching one.
Response: Install and configure
Solstice DiskSuite
before attempting
this task.