Sony 5500 Cassette Player User Manual


 
178
Menu List
Appendix
Other Items (Nos. T01 to ...)
Items T01, T02, and T04 are reset to their factory default
settings whenever the power is turned off.
A10 TC sense data
select
[LINE/24F]
FC/30F
Specifies whether or not the time code information of FC
output signal is returned when time code sense command
is input through the 9-pin connector.
LINE/24F: Time code information of main output signal is
returned. In pulldown conversion mode, 24-frame/sec
time code information is returned.
FC/30F: Time code information of FC output signal is
returned. In pulldown conversion mode, 30-frame/sec
time code is returned.
Notes
Pulldown output signal and 30-frame/sec time code are
synchronized only when this unit is set to PLAY LOCK
mode. To synchronize the signals, set item A05 “PD EXT
SD REF LOCK MODE” to “lock2”.
When editing pulldown output signals with a VTR
operating in 30F mode, it may not be possible to achieve
sync within 5 seconds. If this occurs, set the preroll time
to 7 seconds.
Also, normal operation is not possible with devices
engaged in player sync.
Item number Item Setting Function
T01 AUTO REPEAT
MODE
[off]
on
Selects the repeating operation of PREVIEW in automatic
editing.
off: PREVIEW in automatic editing is not repeated.
on: PREVIEW in automatic editing is repeated. To stop,
press the STOP button.
T02 INTERNAL VIDEO
SIGNAL
GENERATOR (HD)
[off]
COLOR BARS
MULTI BURST 1
MULTI BURST 2
10 STEPS
PULSE & BAR
RAMP
BLACK
Selects the test signal output by the signal generator built
into the VTR.
off: The test signal is not generated, and the VTR operates
normally.
all other settings: The test signal is output from the VTR. At
this time it is also possible to record the signal.
T04 INTERNAL AUDIO
SIGNAL
GENERATOR
[off]
silence
1 kHz sine
Selects the operation of audio test signal output.
off: The audio test signal is not output.
silence: Mute signal.
1 kHz sine: 1 kHz (In this case, a 1 kHz -20 dB FS sine
wave is supplied to all audio inputs.)
Notes
When “silence” or “1 kHz sine” is selected, the AUDIO IN
and AUDIO MONITOR L/R buttons light up.
When the unit is operated in the 23.98 PsF or 24 PsF
mode with “1 kHz sine” selected, the output signal is
960 Hz.
Item number Item Setting Function
Note