Menu List
Appendix
622 CHARACTER H-
POSITION
0
[8]
15
Sets the horizontal position of text information
superimposed on the signal output from the MONITOR
connector of SD SDI OUT, the SD OUT COMPOSITE
connector and HD SDI OUTPUT connector. A setting of 0
displays the information at the left edge of the screen, and
the position moves to the right as the setting is increased.
There are 16 possible settings, from 0 to 15.
623 CHARACTER V-
POSITION
0
[22]
23
Sets the vertical position of text information superimposed
on the signal output from the MONITOR connector of SD
SDI OUT, the SD OUT COMPOSITE connector and HD
SDI OUTPUT connector. A setting of 0 displays the
information at the bottom of the screen, and the position
moves up as the setting is increased. There are 24 possible
settings, from 0 to 23.
Note
If two-line display is selected in item 626, sometimes the
second line will disappear in the middle of the screen.
624 CHARACTER TYPE without BG
outlined
translucent
[with BG]
Sets the style of text information such as time codes output
from the MONITOR connector of SD SDI OUT, the SD OUT
COMPOSITE connector and HD SDI OUTPUT connector.
without BG: White characters, with no background.
outlined: White characters outlined in black.
translucent: White characters on a gray screen
background.
with BG: White characters on a black background.
Note
For the SD SDI OUT connector and SD OUT COMPOSITE
(MONITOR) connector, the “translucent” setting is
automatically changed to “with BG”.
625 CHARACTER SIZE × 1 Sets the size of text information such as time codes output
from the MONITOR of SD SDI OUT, the SD OUT
COMPOSITE connector and HD SDI OUTPUT connectors.
× 1: Normal size.
× 2: Twice normal size.
626 DISPLAY
INFORMATION
select
time data & status
time data & UB
time data & CTL
time data & VITC
[time data only]
When item 620 is set to “on”, this setting specifies the
content of text information output from the MONITOR
connector of SD SDI OUT, the SD OUT COMPOSITE
connector and FORMAT CONV. OUT (OPTION) connector.
time data & status: Timer counter display and status
information.
time data & UB: Timer counter display and user bits.
time data & CTL: Timer counter display and CTL.
time data & VITC: Timer counter display and VITC.
time data only: Timer counter display only.
627 CHAR WARNING
DISPLAY at dual
line mode
[off]
on
When item 626 is set to anything other than “time data
only”, this item specifies whether warning messages flash
on the second line or not.
off: Warning messages do not flash.
on: If a warning message exists, it flashes.
Notes
Messages that have been cleared are not displayed.
For more information about clearing warning messages,
see “Clearing warning messages” on page 138.
When there are multiple warning messages, each
message flashes twice before it is replaced by the next
message.
Item number Item Setting Function
[ 2]
×