Sony 3-270-589-12 (1) CD Player User Manual


 
98
System Menu
Chapter 6 Menus
VITC POS SEL-2 [> VITC pos-2]: Select a line to insert the
VITC in.
Note
You can insert the VITC signal in two places. To insert it in two
places, set both this item and VITC POS SEL-1.
When the system frequency is 60i, 23.98P or 30P
20LINE [>> 20 line] to 12LINE [>> 12 line]: Select any line
from 12 to 20.
Factory default setting: *18 LINE [>> 18 line] (line18)
Note
When the system frequency is 60i, 23.98P, or 30P, the VBID
(Video Blanking ID) receives priority over a selection of
“20LINE”.
When the system frequency is 50i or 25P
22LINE [>> 22 line] to 9LINE [>> 9 line]: Select any line from
9 to 22.
Factory default setting: *21 LINE [>> 21 line] (line 21)
EE OUT PHASE [> EE out]: Determine the output phase for
the LTC signal output from the TIME CODE OUT
connector when recording timecode and in STOP REC
mode (forced E-E mode).
*MUTING [>> muting]: Suppress the output.
THROUGH [>> through]: Output the timecode input to the
TIME CODE IN connector as it is.
VIDEO INPUT PHASE [>> V input]: Output the timecode with
the same phase as the input video signal phase.
VIDEO OUTPUT PHASE [>> V output]: Output the timecode
with the same phase as the output video signal phase.
SEARCH MUTING [> Srch muting]: Select whether to
suppress the output from the TIME CODE OUT connector
in search (jog/shuttle) mode.
OFF [>> OFF] : Do not suppress.
*ON [>> ON]: Suppress.
PD PRESET [> PD preset]: Select the timecode to preset.
The A-frames of pulldown sequences are preset. (This
appears only when 24P (2-3 pulldown) is selected.)
24F TC [>> 24F TC]: Timecode value that becomes the
reference for A-frames.
30F TC [>> 30F TC]: Pulldown value with respect to the above
24-frame timecode.
VITC [> VITC]: Specifies whether or not to record VITC
generated by the internal timecode generator when
recording DVCAM-format signals.
OFF [>> OFF]: Do not record VITC.
*ON [>> ON]: Record VITC.
DISC PROTECTION [Disc protct]: Settings related to disc
protection
Description
STILL TIMER [>> STL timer]: Specify the length of time the
unit can be in still image mode before switching to disc
protection mode.
0.5SEC [>>> 0.5 sec] to 30MIN [>>> 30 min]: Select time
from 16 settings ranging from 0.5 second to 30 minutes.
Factory default setting: *8MIN [>>> 8 min] (8 minutes)
TIME CODE [Time Code]: Settings related to the timecode
generator
Description
VIDEO CONTROL [Video]: Settings related to video
control
Description
INT VIDEO SG [> Video
SG]: Select the test
signal to be output from
the internal test signal
generator. When you set
V INPUT in the HOME
page of the function
menu to “SG”, the
internal signal generator
is activated and outputs
the selected test signal.
You can record this
signal.
HD SIGNAL [>> HD Signal]:
Select the test signal for
HD output.
*100% COLOR BARS [>>> CB100]: 100% color bar signal
RAMP (Y/C) [>>> Ramp]: Bias signal
GRAY [>>> Gray]: Grayscale signal
BLACK [>>> Black]: Black signal
SD SIGNAL [>> SD Signal]:
Select the test signal for
SD output.
*100% COLOR BARS [>>> CB100]: 100% color bar signal
BLACK BURST [>>> BB]: Black burst signal