MIDI Implementation
Data set 1 DT1
Status Data byte Status
F0H 41H, dev, 00H, 6BH, 12H, aaH, bbH, F7H
ccH, ddH, eeH, ... ffH, sum
Byte Explanation
F0H Exclusive status
41H ID number (Roland)
dev Device ID (dev: 00H - 1FH, 7FH)
00H Model ID #1 (Fantom-X6/X7/X8)
6BH Model ID #2 (Fantom-X6/X7/X8)
12H Command ID (DT1)
aaH Address MSB: upper byte of the starting address of the data to be
sent
bbH Address: upper middle byte of the starting address of the data
to be sent
ccH Address: lower middle byte of the starting address of the data
to be sent
ddH Address LSB: lower byte of the starting address of the data to be
sent.
eeH Data: the actual data to be sent. Multiple bytes of data are
transmitted in order starting from the address.
: :
ffH Data
sum Checksum
F7H EOX (End Of Exclusive)
* The amount of data that can be transmitted at one time depends on the type of data, and
data will be transmitted from the specified starting address and size. Refer to the address
and size given in
Parameter Address Map
(P.311).
* Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each
packet will be sent at an interval of about 20 ms.
* Regarding the checksum, please refer to P.329.
* Not received when the Receive Exclusive parameter (SYSTEM/MIDI) is OFF.
Status Data byte Status
F0H 41H, dev, 42H, 12H, aaH, bbH, ccH, F7H
ddH, ... eeH, sum
Byte Explanation
F0H Exclusive status
41H ID number (Roland)
dev Device ID (dev: 10H - 1FH, 7FH)
42H Model ID (GS)
12H Command ID (DT1)
aaH Address MSB: upper byte of the starting address of the transmitted
data
bbH Address: middle byte of the starting address of the transmitted
data
ccH Address LSB: lower byte of the starting address of the transmitted
data
ddH Data: the actual data to be transmitted. Multiple bytes of
data are transmitted starting from the address.
: :
eeH Data
sum Checksum
F7H EOX (End Of Exclusive)
* The amount of data that can be transmitted at one time depends on the type of data, and
data will be transmitted from the specified starting address and size. Refer to the address
and size given in
Parameter Address Map
(P.311).
* Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each
packet will be sent at an interval of about 20 ms.
* Regarding the checksum, please refer to P.329.
* Not received when the Receive Exclusive parameter (SYSTEM/MIDI) is OFF.
2. Data Transmission
Channel Voice Messages
Note off
Status 2nd byte 3rd byte
8nH kkH vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
kk = note number: 00H - 7FH (0 - 127)
vv = note off velocity: 00H - 7FH (0 - 127)
Note on
Status 2nd byte 3rd byte
9nH kkH vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
kk = note number: 00H - 7FH (0 - 127)
vv = note on velocity: 01H - 7FH (1 - 127)
Polyphonic Key Pressure
Status 2nd byte 3rd byte
AnH kkH vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
kk = note number: 00H - 7FH (0 - 127)
vv =
Polyphonic Key Pressure:
00H - 7FH (0 - 127)
Control Change
* By selecting a controller number that corresponds to the setting of parameters of
controllers (REALTIME CONTROL knob, and so on), the Fantom-X can transmit any
control change message.
Bank Select (Controller number 0, 32)
Status
2nd byte 3rd byte
BnH 00H mmH
BnH 20H llH
n = MIDI channel number: 0H - FH (ch.1 - 16)
mm, ll = Bank number: 00 00H - 7F 7FH (bank.1 - bank.16384)
* These messages are transmitted when Patch, Rhythm Set or Performance is selected. But
not transmitted when Transmit Program Change or Transmit Bank Select parameter
(SYSTEM/MIDI) is OFF.
* In Performance mode, these messages are not transmitted when External Bank Select
MSB or External PC Number parameter (PERFORMANCE/PART) is OFF.
* Although with the Fantom-X you can select the Bank Select messages to be transmitted,
be sure to refer to the Program Change Map on P.330 for the Bank Select messages
transmitted when the Fantom-X is select a Patch, Rhythm Set or Performance.
* The Bank Select Numbers corresponding to SRX series should be referred to the SRX
series owner’s manual.
Modulation (Controller number 1)
Status 2nd byte 3rd byte
BnH 01H vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Modulation depth: 00H - 7FH (0 - 127)
Breath type (Controller number 2)
Status
2nd byte 3rd byte
BnH 02H vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Control value: 00H - 7FH (0 - 127)
Portamento Time (Controller number 5)
Status
2nd byte 3rd byte
BnH 05H vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Portamento Time: 00H - 7FH (0 - 127)
Data Entry (Controller number 6, 38)
Status
2nd byte 3rd byte
BnH 06H mmH
BnH 26H llH
n = MIDI channel number: 0H - FH (ch.1 - 16)
mm, ll = the value of the parameter specified by RPN/NRPN
mm = MSB, ll = LSB
Fantom-X678_r_e.book 304 ページ 2005年5月12日 木曜日 午後4時40分