Set Zone 2 (B) product ID -
Each message transmitted from your remote includes a Product Code, identifying
the manufacturer, and Zone product ID code from 1 to 16. The product ID code allows multiple B&K products to
be controlled from the same remote. Your processor actually uses two product ID codes - one for Zone 1 (A)
(normally set to ID code 1) and the other for Zone 2 (B) (normally set to ID code 2). If you have a system with
multiple B&K products then you may wish to set the Zone product ID codes to other values. Note that you cannot
set the Zone 1 (A) product ID to the same setting as Zone 2 (B) or vice versa. If you need to set Zone 1 (A) to the
current Zone 2 (B) setting then set Zone 2 (B) to some other value first.
WARNING - if you change the Zone product ID code in the processor without making the corresponding
change to the remote then the remote will no longer work. Refer to the separate remote manual for details
on changing the remote’s product ID (“device code”).
From Remote From Front Panel Action
1
(PAUSE) or
(STOP)
(UP) or (DOWN) move to Zone ID
2
X
(REW) or
W
(FF)
VOLUME KNOB adjust Zone 2 (B) ID to desired value
Set V2 line output usage -
V2 output is normally set up as a tape loop. The V2 and Zone 2 (B) output are the
current source (V1, TV, CD, DVD, etc.) except when the current selection is V2. When V2 is selected as the
source, the Zone 2 (B) output is V2 and the V2 output is the previously selected source. This prevents feedback
when the V2 inputs and outputs are connected to a tape deck or VCR. Feedback can cause high frequency
oscillations which may damage your speakers. If you don’t connect a tape deck to the V2 input and output you
can use the V2 output as an additional line out. In this mode V2 output is always the selected input including V2.
From Remote From Front Panel Action
1
(PAUSE) or
(STOP)
(UP) or (DOWN) move to V2 Output
2
X
(REW) or
W
(FF)
VOLUME KNOB set for Tape or Line
ADVANCED ZONE B SETTINGS
1 Level Control Variable
2 Fixed Level +15 dB
3 Zone ID 2
4 V2 Output Tape
5 Link Input to Zone A No
6 Link Power to Zone A No
next item adjust
MENU advanced setup
3 Zone ID 2
ADVANCED ZONE B SETTINGS
1 Level Control Variable
2 Fixed Level +15 dB
3 Zone ID 2
4 V2 Output Tape
5 Link Input to Zone A No
6 Link Power to Zone A No
next item adjust
MENU advanced setup
4 V2 Output Tape
ADVANCED ZONE B SETTINGS
1 Level Control Fixed
2 Fixed Level +15 dB
3 Zone ID 2
4 V2 Output Line
5 Link Input to Zone A No
WARNING Connecting a tape
recorder to V2 in LINE mode
can cause speaker damage
next item adjust
MENU advanced setup
4 V2 Output Line