Panasonic PT-DZ16KE Home Theater System User Manual


 
Chapter 4Settings — [PROJECTOR SETUP] menu
ENGLISH - 99
5) Press as to select [MODE].
6) Press qw to switch the item.
f The items will switch each time you press the button.
[OFF] Does not correct the brightness of the screen by the brightness sensor.
[AUTO]
Corrects the brightness of the screen by the brightness sensor.
Automatically corrects screen brightness when lamp brightness changes.
[PC]
Synchronizes nine or more projectors through a computer using the dedicated software “Multi
Projector Monitoring & Control Software”
*1
.
*1 “Multi Projector Monitoring & Control Software” is included in the supplied CD-ROM.
f When [AUTO] is selected, proceed to Step 7).
7) Press as to select [LINK].
8) Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
Performs corrections by the brightness sensor in one projector without synchronizing with the other
projectors.
The period, in which the constant brightness kept by the small value of [BRIGHTNESS CONTROL
GAIN], is prolonged.
[GROUP A]
[GROUP B]
[GROUP C]
[GROUP D]
Synchronizes corrections in multiple projectors by the brightness sensor.
You can set up to four groups (A to D) within the same subnet by using the network function.
You can also register and synchronize up to eight projectors in one group.
9) Press as to select [CHROMA CORRECTION].
10) Press qw to switch the item.
f The items will switch each time you press the button.
[OFF] Corrects only brightness.
[ON] Corrects both brightness and color.
11) Press as to select [CALIBRATION TIME].
12) Press the <ENTER> button.
f Enters adjustment mode (the display is blinking).
13) Press qw to select “hour” or “minute”, and press as or the number (<0> ‑ <9>) buttons to set a
time.
f Selecting “hour” allows setting of only the hour in increments of one hour, and selecting “minute” allows setting of only the minute in
increments of one minute between 00 and 59.
f If you do not specify the time, select [OFF] between 23 and 00 o’clock or between 59 and 00 minutes.
14) Press the <ENTER> button.
f [CALIBRATION TIME] is set.
f Brightness and color are measured at the specied time. Dynamic iris is xed to open during measurement.
15) Press as to select [CALIBRATION MESSAGE].
16) Press qw to switch the item.
f The items will switch each time you press the button.
[ON] Messages are displayed during calibration.
[OFF] Messages are not displayed during calibration.
17) Press as to select [APPLY].
18) Press the <ENTER> button.
f The set [MODE] and [LINK] are enabled, and LAMP RELAY screen alert is displayed when the [LAMP RELAY] setting is [OFF]. When
[CALIBRATION MESSAGE] is set to [ON], a calibration running message is displayed which will automatically disappear 30 seconds
after calibration completes.
f If the <ENTER> button is pressed with [MODE] in [BRIGHTNESS CONTROL SETUP] set to other than [OFF], the brightness and color
of the lamp at the time the button was pressed is recorded as a standard.