Dolby Laboratories DP570 Stereo System User Manual


 
Using the DP570 in Master Control Typical Activities
Dolby
®
DP570 Multichannel Audio Tool User’s Manual 59
Figure 8-2 Typical Downmix Options
Or,ifaviewercomplainsabouttheaudio qualityonamonotelevisionwhenviewing a5.1
program,theMCoperatorcanquicklyselectMonointheDownmixsection,andRFto
emulatetheviewerʹslisteningconditions.
8.2.2 Monitoring Dialogue Level
Whenchangingprogramsorchannels,refertothedialoguelevelindicatorstoverifythat
theDialogueLevelvaluesetinthe software—thegreennumbersinFigure 83—andthe
measuredvalue—theyellownumbersinFigure 83—ofspeechmatch±2dB.
Figure 8-3 Dialogue Level Controls
IftheDialogueLevelvaluedoesn’tmatch,werecommendadjustingtheoverallaudiolevel
untilitdoes.
Inmostcasesshorttermmeasurementsarebestastheyprovide ameasurementoveraten‐
secondperiodofprogramaudioanddonotaveragethemeasurementoveralongperiod
oftime.For
moreinformationonthemeasurementmodes,seeMeasuringtheAverage
LoudnessofIdentifiedClipsonpage 31.
Note:Asingleprogrammusthaveasingledialnormvalue,andthisvalueshouldnot
changewithintheprogram.Adjustaudiolevelstomatchdialnormifnecessary,
ratherthantheotherwayaround.