Using the DP570 Features Sticky Settings
4.17 Sticky Settings
WhenyouenableStickySettings,yourlastsettingsfordynamicrangecontrolprofiles,
downmix,speakerselection,LFEmonitor,mastervolume,and emulatorbypassforyour
listeningenvironmentremainwitheachprogramwhenyouleaveoneprogramtomonitor
another.Thisallowsyoutoswitchtoanotherprogram,monitorthatprogram,
thenreturn
totheoriginalprogramwithoutlosingthesettingsyouhadchosenfortheoriginal
program.
WhenyoudisableStickySettings,settingsforthesemonitoringmodesdonotchange
whenyouleaveoneprogramtomonitoranother.
Bydefault,StickySettingsisenabled.Toturnitoff,uncheckthebox.
4.18 Lt/Rt Gain Function
ThiscontrolallowsyoutocontrolgainoftheLt/Rtinput.
TotrimtheLt/RtinputlevelintheDolbyRemote570:
1. ClickSetupintheMainwindowtoopentheSetupwindow.
2. UsetheupanddownarrowstoincreaseordecreasethedefaultLt/Rtgain.
Figure 49showstheLt/RtGaincontrol
ontheSetupwindow.
Figure 4-9 Lt/Rt Gain Control
4.19 Dim Function
TheDimbuttonenablesyoutochangeyourmonitorlevelwithoneclick.Clickit,for
instance,ifaclientwalksinoryouhavetotakeap honecall.Returntoyourmasterlevel
settingbyclickingDimagain.
4.20 Master Trim and Master Volume
TheMasterTrimsliderallowsyoutoraiseorlowerthevolumeofthesignalinputtothe
DP570beforeprocessingbegins.Thiscapabilityisveryusefulinlisteningenvironment
calibrationprocess.