Wolf DCX-1500FD Home Theater System User Manual


 
Wolf Cinema Owner's Manual
B-22
FRD Frame Delay
Use FRD to adjust the number of lines of delay between the input and output frames (range
varies with incoming signal).
FRZ Freeze Image
FRZ 1 = freeze the image. FRZ 0 = unfreeze the image.
FSE Fan Sensor Enable
Use FSE if you want the projector to shut down 3 minutes after a critical cooling fan failure. FSE
1=enabled,FSE0=disabled.NOTE:Denitionofawhichcoolingfaniscriticalvarieswith
projector model.
FYI For Your Information
The projector broadcasts an FYI message when it detects a change in status. The FYI message
contains the relevant status code followed by its new state (P1), up to 2 additional parameters of
detail, and a brief text description. The address of the source projector precedes the FYI code.
NOTE: FYI messages are gated by the Error Message Enable (EME) control. Turning off EME
also turns off FYI.
Status Code New State (P1) Meaning and Additional Parameters
001 Power 0 = Off 1 = On 2 = Boot 10
= Cool Down 11 = Warm Up
P1 value indicates the new “Power” state
detected.
002 Proj. Address ##### (5-digit address) P1 value indicates the new address of
this source projector.
003 Proj. Selected 0 = RS232 Inactive, UI
Inactive 1 = RS232 Inactive,
UI Active 2 = RS232 Active,
UI Inactive 3 = RS232
Active, UI Active
This projector has been activated or
inactivated via the PROJ key or the APJ
serial message.
004 Baud Rate ####### (7-digit baud rate) P1 value indicates the new baud rate.
005 Standby 0 = Off 1 = On P1 value indicates whether the system is
in standby mode
006 Signal 0 = Good Signal 1 = Signal
missing 2 = bad sync
P1 describes signal detection P2 = hor.
frequency of signal P3 = vert. frequency
of signal
007 OSD 0 = Off 1 = On P1 value indicates whether the on-
screen display is on or not.
009 Shutter 0 = Open 1 = Closed P1 value indicates whether the shutter is
open or closed.
010 Input 0 = Open 1 = Closed P1 describes the current channel
number P2 = Switcher# (projector is
always switcher “000”) P3 = Slot#
011 Picture Mute. 0 = Off 1 = On P1 value indicates whether the picture is
displayed or not
012 PIP. 0 = Off 1 = On P1 value indicates whether Picture-in-
Picture mode is on or not
255 General / Misc. ### (3-digit channel
number)
P1 describes miscellaneous general
state detected
3.53 FRD
Frame Delay
3.54 FRZ
Freeze Image
3.55 FSE
Fan Sensor Enable
3.56 FYI
For Your Information
AppendixB►SerialCommunications