Wolf DCX-1500FD Home Theater System User Manual


 
Wolf Cinema Owner's Manual
B-21
Examples:
NOTE: The 65535 signies the port address of the controller receiving the message.
SYNC no longer responding (65535 00030ERR 001 "System Error: SYNC no longer
responding")
Attempt to delete the current source (65535 00030ERR 002 "System Warning: The current
source cannot be deleted")
(BDR38900) (65535 00030ERR 003 "BDR: Invalid parameter 1")
(BLB 25 25) (65535 00030ERR 004 "BLB: Too many parameters")
(ASR S10) (65535 00030ERR 005 "ASR: Too few parameters")
(ASR S10 1) (65535 00030ERR 006 "ASR: Source does not exist")
(CON 45) with no source (65535 00030ERR 007 "CON: Could not be executed")
(&con 64 250) (65535 00030ERR 008 "CON: Checksum Error")
(ABC?) (65535 00030ERR 009 "ABC: Unknown request")
FAD Fade Time
Use FAD to set the time for dissolving one display image into the next (0=seamless, 100=1
second). Or, if using v1.0 software, FAD sets the time for fading to black and then to the new
display image.
FCS Focus
The FCS adjusts lens focus on projectors having a motorized lens mount, and requires keypad
emulation.
Examples:
(FCS K3) –ve Focus direction
(FCS K2) +ve Focus direction.
(FCS K0) Stop focus adjustment (if not issued, lens movement will continue
until it reaches the end stop).
To “nudge” the focus a minimum amount, script in a delay between (FCS K3) and (FCS K0).
Dependingonyourapplication,adelayofatleast20-30millisecondsmaybesufcient.
FIL Input Filter
UseFILtoforceaninternallterforHDTV(1),SDTV(2),EDTV(3),Graphics/RGB(4)ortoturn
theautomaticlteringfeatureoff(0).Thisautomaticlterisforanalogsourcesonly.
FLE Frame Lock Enable
UseFLEtodenehowtheprojectorcontrolstheoutputframetimingbasedontheinputsignal.
Use the following parameters to achieve the desired output frame timing.
P1 = 0: Rate Matched – the output runs at close to the input frequency but is not locked to it so
the output will drift in phase relative to the output.
P1 = 1: Locked – if possible the output image is phase locked to the input frames
P1 = 2: Free Run – the output runs at 60Hz frame rate
For older versions of software (v1.1 and earlier) this control is a checkbox to enable a “Locked”
output. When unchecked the output is “Frame Matched”.
FMT 2/3 Pull Down Threshold
Use FMT to adjust the threshold (0-255) at which the projector will consider an incoming video
signalaslmvs.video.
3.48 FAD
Fade Time
3.49 FCS
Focus
3.50 FIL
Input Filter
3.51 FLE
Frame Lock Enable
3.52 FMT
2/3 Pull Down Threshold
AppendixB►SerialCommunications