Option AYF Tachometer Parameters
Parameter Default Value Changes
active Off Abort
input_high Normal Immediate
pre_arm_rpm 600 RPM Immediate
rpm_high 6000 RPM Immediate
rpm_interval 25 RPM Immediate
rpm_low 600 RPM Immediate
rpm_smoothing 0 Immediate
tach_decimate 0 Immediate
tach_holdoff 10 µs Immediate
tach_max_time 30 s Immediate
tach_ppr 1 Immediate
trigger_channel Off Wait
trigger_level_lower -0.05 volts Immediate
trigger_level_upper 0 volts Immediate
trigger_slope Positive Immediate